首页 > 代码库 > 查看服务器型号、SN、Raid等信息
查看服务器型号、SN、Raid等信息
一、查看服务器型号
安装dmidecode
yum install dmidecode
1、查看服务器型号、SN信息
# dmidecode -t 1 # dmidecode 2.11 SMBIOS 2.7 present. Handle 0x0024, DMI type 1, 27 bytes System Information Manufacturer: IBM Product Name: IBM System x3650 M4: -[79159NZ]- Version: 0C Serial Number: 06BZCLH UUID: AF399A1C-0C8C-11E4-B599-40F2E92D9F02 Wake-up Type: Power Switch SKU Number: Not Specified Family: System X
二、查看Raid组磁盘状态,SN等 (需要安装MegaCli ,下载地址:http://pan.baidu.com/s/1i4W6ERb )
1、查看磁盘raid卡厂商
# dmesg | grep -i raid megaraid_sas 0000:16:00.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 megaraid_sas 0000:16:00.0: setting latency timer to 64 megaraid_sas 0000:16:00.0: irq 89 for MSI/MSI-X scsi0 : LSI SAS based MegaRAID driver scsi 0:0:0:0: Direct-Access IBM ServeRAID M5110e 3.34 PQ: 0 ANSI: 5 scsi 0:0:1:0: Direct-Access IBM ServeRAID M5110e 3.34 PQ: 0 ANSI: 5 scsi 0:2:0:0: Direct-Access IBM ServeRAID M5110e 3.34 PQ: 0 ANSI: 5 scsi 0:2:1:0: Direct-Access IBM ServeRAID M5110e 3.34 PQ: 0 ANSI: 5 md: Autodetecting RAID arrays.
2、查看磁盘物理信息
# /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll Adapter #0 Enclosure Device ID: 8 Slot Number: 0 Drive‘s postion: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: 0 Device Id: 22 WWN: 5000C500725C991C Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Online, Spun Up ---磁盘状态 Is Commissioned Spare : NO Device Firmware Level: B56M Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c500725c991d SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSST300MM0006 B56MS0K29RW30221B5C5 IBM FRU/CRU: 41Y8376 ----磁盘SN FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :32C (89.60 F) PI Eligibility: Yes Number of bytes of user data in LBA: 512 Drive is formatted for PI information: Yes PI: PI with type 2 Drive‘s write cache : Enabled Port-0 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No ... ... ... Enclosure Device ID: 8 Slot Number: 3 Drive‘s postion: DiskGroup: 0, Span: 1, Arm: 1 Enclosure position: 0 Device Id: 12 WWN: 5000CCA0542353E3 Sequence Number: 4 Media Error Count: 0 Other Error Count: 330
Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Failed ----磁盘状态
Device Firmware Level: J2EG Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000cca0542353e1 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSHUC109030CSS60 J2EGKFGME97RJ2EGJ2EGJ2EG IBM FRU/CRU: 90Y8878 --磁盘FRU FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :31C (87.80 F) PI Eligibility: Yes Number of bytes of user data in LBA: 512 Drive is formatted for PI information: Yes PI: PI with type 2 Drive‘s write cache : Enabled Port-0 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No ... ... ...
3、查看所有Virtual Disk的状态(可以查看到raid级别,每个raid对应的硬盘)
RAID Level对应关系:
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 | RAID 1 |
RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 | RAID 0 |
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3 | RAID 5 |
RAID Level : Primary-1, Secondary-3, RAID Level Qualifier-0 | RAID 10 |
# /opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aAll -NoLog Adapter #0 Number of Virtual Disks: 2 Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 1.086 TB Mirror Data : 1.086 TB State : Optimal Strip Size : 128 KB Number Of Drives per span:2 Span Depth : 4 Default Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Enabled Encryption Type : None PI type: Proprietary type Is VD Cached: No Number of Spans: 4 Span: 0 - Number of PDs: 2 PD: 0 Information Enclosure Device ID: 8 Slot Number: 0 Drive‘s postion: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: 0 Device Id: 22 WWN: 5000C500725C991C Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: B56M Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c500725c991d SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSST300MM0006 B56MS0K29RW30221B5C5 IBM FRU/CRU: 41Y8376 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: Yes Number of bytes of user data in LBA: 512 Drive is formatted for PI information: Yes PI: PI with type 2 Drive‘s write cache : Enabled Port-0 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No PD: 1 Information Enclosure Device ID: 8 Slot Number: 1 Drive‘s postion: DiskGroup: 0, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 21 WWN: 5000C50075E5DD88 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: B56M Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50075e5dd89 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSST300MM0006 B56MS0K2DX3J0221B5C5 IBM FRU/CRU: 41Y8376 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: Yes Number of bytes of user data in LBA: 512 Drive is formatted for PI information: Yes PI: PI with type 2 Drive‘s write cache : Enabled Port-0 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No ... ... ... Virtual Drive: 1 (Target Id: 1) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 1.816 TB Mirror Data : 1.816 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 2 Default Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Enabled Encryption Type : None PI type: Proprietary type Is VD Cached: No Number of Spans: 2 Span: 0 - Number of PDs: 2 PD: 0 Information Enclosure Device ID: 8 Slot Number: 8 Drive‘s postion: DiskGroup: 1, Span: 0, Arm: 0 Enclosure position: 0 Device Id: 17 WWN: 5000C50058D8AD00 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 930.390 GB [0x744c8000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: BD2H Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50058d8ad01 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSST91000640SS BD2H9XG6Y2F01119BD31 IBM FRU/CRU: 81Y9691 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :33C (91.40 F) PI Eligibility: Yes Number of bytes of user data in LBA: 512 Drive is formatted for PI information: Yes PI: PI with type 2 Drive‘s write cache : Enabled Port-0 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No PD: 1 Information Enclosure Device ID: 8 Slot Number: 9 Drive‘s postion: DiskGroup: 1, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: 5000C50058D278CC Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 931.512 GB [0x74706db0 Sectors] Non Coerced Size: 931.012 GB [0x74606db0 Sectors] Coerced Size: 930.390 GB [0x744c8000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: BD2H Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50058d278cd SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSST91000640SS BD2H9XG6XGAD1119BD31 IBM FRU/CRU: 81Y9691 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :32C (89.60 F) PI Eligibility: Yes Number of bytes of user data in LBA: 512 Drive is formatted for PI information: Yes PI: PI with type 2 Drive‘s write cache : Enabled Port-0 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port‘s Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No ... ... ... Exit Code: 0x00
或者只查看raid级别
# /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 1.086 TB Mirror Data : 1.086 TB State : Optimal Strip Size : 128 KB Number Of Drives per span:2 Span Depth : 4 Default Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Enabled Encryption Type : None PI type: Proprietary type Is VD Cached: No Virtual Drive: 1 (Target Id: 1) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 1.816 TB Mirror Data : 1.816 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 2 Default Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Enabled Encryption Type : None PI type: Proprietary type Is VD Cached: No Exit Code: 0x00
3.在线做Raid
/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r0[0:11] WB NORA Direct CachedBadBBU -strpsz64 -a0 -NoLog /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [12:2,12:3,12:4,12:5,12:6,12:7] WB Direct -a0
4.点亮指定硬盘(定位)
/opt/MegaRAID/MegaCli/MegaCli64 -PdLocate -start -physdrv[252:2] -a0
5.清除Foreign状态
/opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Clear -a0
6.查看RAID阵列中掉线的盘
/opt/MegaRAID/MegaCli/MegaCli64 -pdgetmissing -a0
7.替换坏掉的模块
/opt/MegaRAID/MegaCli/MegaCli64 -pdreplacemissing -physdrv[12:10] -Array5 -row0 -a0
8.手动开启rebuid
/opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -start -physdrv[12:10] -a0
9.查看Megacli的log
/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog dsply -a0 > adp2.log
10.设置HotSpare
/opt/MegaRAID/MegaCli/MegaCli64 -pdhsp -set [-Dedicated [-Array2]] [-EnclAffinity] [-nonRevertible] -PhysDrv[4:11] -a0 /opt/MegaRAID/MegaCli/MegaCli64 -pdhsp -set [-EnclAffinity] [-nonRevertible] -PhysDrv[32:1}] -a0
11.关闭Rebuild
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAutoRbld -Dsbl -a0
12.设置rebuild的速率
/opt/MegaRAID/MegaCli/MegaCli64 -AdpSetProp RebuildRate -30 -a0
13.查看某块磁盘重构进度
#/opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ShowProg -PhysDrv [1:5] -a0
查看服务器型号、SN、Raid等信息
声明:以上内容来自用户投稿及互联网公开渠道收集整理发布,本网站不拥有所有权,未作人工编辑处理,也不承担相关法律责任,若内容有误或涉及侵权可进行投诉: 投诉/举报 工作人员会在5个工作日内联系你,一经查实,本站将立刻删除涉嫌侵权内容。