HP服务器重装centeos 6.3红屏错误码 Illegal Opcode

公司组装一个服务器要装centos 6.3 .出现一个问题 如果自动引导一切正常.如果手动分区重启后就会,红屏错误码 Illegal Opcode. 

去网上问度娘各种不靠谱,有时说要 升级BIOS,从新做raid 了 各种不靠谱.自动引导正常表明绝对是系统安装问题.

试图 google 结果404 好吧 退而求其次 bing  直接bing Illegal Opcode 排除几个度娘过的中文站看到一个英文站 直接 翻译此页

终于找到句 

HP ProLiant DL580 G5: Illegal Opcode on boot

After a nightmarish 24 hours, I‘ve successfully installed Ubuntu 10.04 x86-64 Server on an HP ProLiant DL580 G5 server with an added P800 Raid Controller device. I wanted to make a public record on the steps to finish the installation in case it helps anyone in the future.

The issue we were running in to was the message "Illegal Opcode" given after BIOS startup before the OS could load, even after a successful OS installation. HP support confirmed that this message is given when the MBR on the boot controller does not refer to a valid bootable partition.

HP ProLiant DL580 G5: 非法操作码开机

后一个噩梦般的 24 小时,我已经成功安装 Ubuntu 10.04 x 86-64 服务器 HP ProLiant DL580 G5 服务器上与添加的 P800 Raid 控制器设备。我想要的公开记录的步骤以完成安装,以防它在将来帮助任何人。

这一问题被磨合到了消息之前操作系统无法加载,即使在操作系统安装成功后给予在 BIOS 启动后的"非法操作码"。HP 支持证实了此消息给出了当 MBR 引导控制器上的不是指一个有效的引导分区。
好吧 MBR 引导控制器上的不是指一个有效的引导分区,就是引导驱动没有写到硬盘里(引导盘不对)
centos6.3 界面安装最后一步 选择引导盘时 两个都改成硬盘(U盘不选,不确定这个操作是否有效) 然后选择 第一个radio button 哈哈 就是/sdb 然后重启 OK
学好英语很重要,技术问题baidu 不靠谱
原链接:buntuforums.org/showthread.php?t=1613584
 