首页 > 代码库 > 2000DM001-1CH164 CC27 Z340GAMF 100717520-VER B

2000DM001-1CH164 CC27 Z340GAMF 100717520-VER B

HDD family detecting...
Family ID: 58


Selected family......................... : 58, Grenada
Model by ID............................. : ST2000DM001-1CH164

Loading default settings!
Use the options dialog to review and save utility settings.
Then press OK!


Family default settings loading!


Tech Key...

Requesting FW Pkg ver ........ GPX17C.CCD2.DC05AL.CC27


Detecting Phys Sct Size...
Result.................................. : 4096

Detecting Max Head number...
Phys. heads............................. : 4

Obtaining Saved Mode Pages File information...
Reading Saved Mode Pages...
Parsing Saved Mode Pages...
SMP Dbl: 0x3C001000 - 0x0001FFFF (0x0000000F)

LBA alignment........................... : 0

Obtaining Registry File information...
Reading Registry File...
Parsing Registry File...

Media Cache
===========
MC : enabled
MC Size : 0x43EE50
MCMT Ver : MCMTV05

Collecting Sys Files information...
ID Len
===============
0 36 Reserved Defect Table (SA defect table)
1 2 Drive Information File (DIF)
2 16 Performance Parameter File (PPF)
3 7782 Primary Defect File (P-List))
5 4 Manufacturing Information File (MIF)
8 4800
B 1000
C 122880 Serial Port Test Results File (Self Scan Log)
D 160
E 432 Data Integrity Check (DIC), HEAD 0
F 223 DIC Dummy File
13 8 Disc Registry File (settings, security, etc)
15 100 BGMS File (Directed Offline Scan)
16 2
17 40
19 24 Log File
1A 33 Log File
1B 1 Log File
1C 9
1D 128 Physical Overlay File 0
1E 128 Physical Overlay File 1
22 80 Drive Self Test (DST), Head 0
23 80 Drive Self Test (DST), Head 1
24 80 Drive Self Test (DST), Head 2
25 80 Drive Self Test (DST), Head 3
2A 9 Saved Mode Pages (HDD settings)
2B 10118 R/W Operating Parameters (translator, etc)
2C 432 Data Integrity Check (DIC), HEAD 1
2D 432 Data Integrity Check (DIC), HEAD 2
2E 432 Data Integrity Check (DIC), HEAD 3
33 4576
34 640 Packed CONGEN XML definition
39 8192
3A 4
3D 3072
3E 3072
3F 4576
40 7
41 2180
42 4096
43 10241
44 1357032
45 226172
46 226172
47 226172
48 226172
49 226172
4A 226172
4B 8192
4F 14336
51 18432
52 1024
53 8192
54 3984384
Collecting Sys File Infos completed

Collecting DT Infos...
ROM:
ID MemOffs Len
===========================
0 40030200 40944 Read Adaptive Parameters File (RAP)
1 40030000 512 Controller Adaptive Parameters File (CAP)
4 1D400 7168 Servo Adaptive Parameter File (SAP)
40002000 13288
total 20456
5 6C000 81920 Servo Firmware Table
A 25EA90 1024 Seek Profile
13 401393F8 1440 Dependent Zone Table for User Area
14 40139998 120 Dependent Zone Table for System Area
15 0 524288 Flash ROM
1D 40030220 424 VBAR Configuration File
1E 400305B8 4016 Zone Format Parameters File
26 40136F28 9424
27 40136D30 504

RAM:
ID MemOffs Len
===========================
0 40030200 40944 Read Adaptive Parameters File (RAP)
1 40030000 512 Controller Adaptive Parameters File (CAP)
2 400303C8 496 Zone Table
4 1D400 7168 Servo Adaptive Parameter File (SAP)
40002000 13288
total 20456
5 6C000 81920 Servo Firmware Table
6 1915C40 81964 Servo Flaw Table
A 25EA90 1024 Seek Profile
13 401393F8 1440 Dependent Zone Table for User Area
14 40139998 120 Dependent Zone Table for System Area
15 0 524288 Flash ROM
16 40030200 32 Drive Configuration Table
17 400319A0 2016 Temperature Control Configuration
1D 40030220 424 VBAR Configuration File
1E 400305B8 4016 Zone Format Parameters File
1F 4032C8E8 4500 RW working user preamp table
20 4032DA80 150 RW working system preamp table
26 40136F28 9424
27 40136D30 504

Collecting DT Infos completed


Reading autotuning buffer............... Ok
Searching module table in RAM........... Ok
Searching volume 3 file table in RAM.... Ok
Searching volume 0 file table in RAM.... Ok
Searching SMP RAM FID in RAM............ Ok
Searching Non Resident G-List FID in RAM Ok
Searching CFW OVL FID in RAM............ Ok
Searching DT table(RAM, WR) in RAM...... Ok
Searching DT table(RAM, RD) in RAM...... Ok

System Files I/O method detection... ATA(direct)

 

备份固件的时候:额.................最后貌似板坏了,原因不知..........

Reading DT to DB
Folder: <root>/Seagate F3 Architecture/Grenada/ST2000DM001-1CH164 CC27 Z340GAMF 100717520-VER B/CPDir

DT 0000 (Flash ROM), Read Adaptive Parameters File (RAP).............. : Error
Error : Rq Rd DT part ID 0, Offs 0x0 err! Tech state 0x72, 0x05260207
DT 0001 (Flash ROM), Controller Adaptive Parameters File (CAP)........ : Ok
DT 0004 (Flash ROM), Servo Adaptive Parameter File (SAP).............. : Error
Error : Rq Rd DT part ID 4, Offs 0x0 err! Tech state 0x72, 0x05260207
DT 0005 (Flash ROM), Servo Firmware Table............................. : Ok
DT 000A (Flash ROM), Seek Profile..................................... : Ok
DT 0013 (Flash ROM), Dependent Zone Table for User Area............... : Ok
DT 0014 (Flash ROM), Dependent Zone Table for System Area............. : Ok
DT 0015 (Flash ROM), Flash ROM........................................ : Ok
DT 001D (Flash ROM), VBAR Configuration File.......................... : Ok
DT 001E (Flash ROM), Zone Format Parameters File...................... : Ok
DT 0026 (Flash ROM)................................................... : Ok
DT 0027 (Flash ROM)................................................... : Ok
DT 0000 (RAM), Read Adaptive Parameters File (RAP).................... : Ok
DT 0001 (RAM), Controller Adaptive Parameters File (CAP).............. : Ok
DT 0002 (RAM), Zone Table............................................. : Ok
DT 0004 (RAM), Servo Adaptive Parameter File (SAP).................... : Ok
DT 0005 (RAM), Servo Firmware Table................................... : Ok
DT 0006 (RAM), Servo Flaw Table....................................... : Ok
DT 000A (RAM), Seek Profile........................................... : Ok
DT 0013 (RAM), Dependent Zone Table for User Area..................... : Ok
DT 0014 (RAM), Dependent Zone Table for System Area................... : Ok
DT 0015 (RAM), Flash ROM.............................................. : Ok
DT 0016 (RAM), Drive Configuration Table.............................. : Ok
DT 0017 (RAM), Temperature Control Configuration...................... : Ok
DT 001D (RAM), VBAR Configuration File................................ : Ok
DT 001E (RAM), Zone Format Parameters File............................ : Ok
DT 001F (RAM), RW working user preamp table........................... : Ok
DT 0020 (RAM), RW working system preamp table......................... : Ok
DT 0026 (RAM)......................................................... : Ok
DT 0027 (RAM)......................................................... : Ok
DT reading process completed
Result.................................. : Error

Reading modules to DB
Folder: <root>/Seagate F3 Architecture/Grenada/ST2000DM001-1CH164 CC27 Z340GAMF 100717520-VER B/ModDir

Will be skipped : 000C, 000E, 000F, 0022, 0023, 0024, 0025, 002C, 002D, 002E, 0044, 0045, 0046, 0047, 0048, 0049, 004A

Module 0000, Reserved Defect Table (SA defect table).................. : Ok
Module 0001, Drive Information File (DIF)............................. : Ok
Module 0002, Performance Parameter File (PPF)......................... : Ok
Module 0003, Primary Defect File (P-List))............................ : Ok
Module 0005, Manufacturing Information File (MIF)..................... : Ok
Module 0008........................................................... : Ok
Module 000B........................................................... : Ok
Module 000D........................................................... : Ok
Module 0013, Disc Registry File (settings, security, etc)............. : Ok
Module 0015, BGMS File (Directed Offline Scan)........................ : Ok
Module 0016........................................................... : Ok
Module 0017........................................................... : Ok
Module 0019, Log File................................................. : Ok
Module 001A, Log File................................................. : Ok
Module 001B, Log File................................................. : Ok
Module 001C........................................................... : Ok
Module 001D, Physical Overlay File 0.................................. : Ok
Module 001E, Physical Overlay File 1.................................. : Ok
Module 002A, Saved Mode Pages (HDD settings).......................... : Ok
Module 002B, R/W Operating Parameters (translator, etc)............... : Ok
Module 0033........................................................... : Ok
Module 0034, Packed CONGEN XML definition............................. : Ok
Module 0039........................................................... : Ok
Module 003A........................................................... : Ok
Module 003D........................................................... : Ok
Module 003E........................................................... : Ok
Module 003F........................................................... : Ok
Module 0040........................................................... : Ok
Module 0041........................................................... : Ok
Module 0042........................................................... : Ok
Module 0043........................................................... : Ok
Module 004B........................................................... : Ok
Module 004F........................................................... : Ok
HDD power supply switching OFF/ON...
Module 0051........................................................... : Error
Error : Drive not ready
Modules reading process completed

Reading HDD ID pages list...

Backup of service information completed

Drive not ready